Ariana Orellana asked ... Code?    |    Lynnie asked ... BT Studio 4500 cordless telephone?    |    David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Michael asked ... Mountfield empress drive belt?    |    Click here to ask your question

Britony Combi SE 70 80 Error + Low Pressure?

Hi all,

My boiler is showing the "No Flame Detected" error but in addition the CH pressure gauge shows that the pressure is only about .75.
I have tried adjusting the valves on the filling loop but it doesn't seem to make any difference. I am assuming that the filling loop is the silver pipe under the boiler...?
Anyone have any ideas?
I may be being a bit of an idiot and not using the valves properly on the loop, I suppose...
Thanks a lot.
Mat, March 2010
britony se 80. pressure should be 1.5bar.the loop is under the boiler joining the incoming feed to the central heating these are the 2 last pipes on the right.open valve on this pipe until 1.5 shows.if you have lost pressure you may have a leak.no flame detection means the ionization electrode has not detected a flame.maybe electrode has failed (£40) or pcb has failed (£130+). leak needs sorting to see if 70 80 fault goes.when power is isolated elecrode contacts can be cleaned and pcb checked out.

xs11, March 2010