Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

Why can I not set my alarm system?

Optimax XM6 system.

Basically, when decorating a room I accidently cut through one of the sensors alarm wiring - I had enough 'play' on the wire so simply re-wired it into the sensor.

The alarm is currently on day mode as per usual but when I enter my code to set it it just has the red lights on all three of my zones and makes a beeping noise (different to the set noise). None of the sensors are sensing either as the red light on them is not flashing.

I have triple checked the wiring and have reset the system to factory default ... anyone suggest anything else?
Chris, May 2010
If you cut through the cable you will have blown the glass circuit fuse supplying 13v to the PIR's, check and replace.

downtoearth, May 2010
By the way asking more than once is pointless

acorn, May 2010