Marc Nollid asked ... Nissan Micra mk 5 2018 rear seat mecanism?    |    Maggie asked ... New Home 535?    |    paul asked ... Hook timing Janome QC 6260?    |    David asked ... Beeper bust?    |    Tom asked ... Service manual for Lawnflite 908LA?    |    Click here to ask your question

upvc widow repair?

i have a UPVC window in my bedroom that has let condensation in between the 2 panes of glass, Can this be fixed or do i have to buy a new window, i think its the seals that have gone, & the condensation stays there all the time and looks awful, plz help
D.Thomas, September 2010
it`s only the glass unit that needs replacing.
remove the beading and take out the glass unit. measure the width, height and importantly the thickness. they are of varying thickness eg.
22mm 24mm 28mm. also check if it is toughened glass, there will be a kite mark if it is. now if any unit from floor level to visible level of glass is below 800mm then it has to be toughened but you can change like for like. also is the inner pane of glass `k` glass? go to a glass manufacturer not a window manufacturer it`s much cheaper.

levilewy, September 2010