Tom asked ... Service manual for Lawnflite 908LA?    |    John asked ... Scantronics 9450 box stuck shut?    |    Pekaye asked ... Clutch Cable change?    |    Richard asked ... Mountfield SP414 mower, revs too high?    |    Don asked ... Find the charger or how to convert the battery?    |    Click here to ask your question

vokera excell sp ?

hot water is tepid and appears to heat radiators yet when radiators are on water isturned on water is hot
alan, January 2011
Needs servicing, presumably the three port valve isnt being operated properly, probably because the DHW diaphragm has a hole (very common problem). When the diaphragm is replaced make sure all traced of old diaphragm rubber are cleaned off the pusher plate and brass insides or you will be replacing it again within the year. This, along with dirty venturi caused hot water cycling is a very common fault on this model.
Download the manual from Vokera if you need diagrams.