Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Steve asked ... Gilera runner 180 vxr 2001 ignition replacement?    |    Click here to ask your question

My Riello 40 loses it prime ?

I have a Riello 40 and for some reason it doesn't hold its prime, I have to bleed it at lease once and even twice a day in order for it to keep it running.
Jim, February 2011
air is getting into you line somewhere, check all the connections in your flexable oil lines are tight as well as the bleeding screw on the pump (the one marked V) if you hold your finger over a water filled hosepipe the water dosn``t run out, if a little air gets in the water runs out, these are the easiest thing to check first hope it helps

Peter, February 2011