42 mins ago Richard asked ... Mountfield SP414 mower, revs too high?    |    Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    Click here to ask your question

Does anyone know what fault H5 means on an Isar HE30 boiler?

The PCB has been replaced and is now flashing H, 5 and will not re-set, can you help?
Donna Robertson, May 2011
the pcb has to be configured for that particular model of boiler by placing jumper link pins in a particular sequence

if you look at the old pcb
look at the top right hand corner
there should be a couple of black plastic tangs linking a series of pins

all you have to do is transfer the old pins to the exact same position on the new pcb & hey presto your boiler will work

manwithnoname, May 2011