3 hours ago Dave asked ... Repair kettle lid?    |    Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Click here to ask your question

Vaillant 242 boiler keeps blowing 2 amp fuses?

Vaillant 242 boiler keeps blowing 2 amp fuses when boiler control dials are moved, boiler will not fire up ?
Patrick Wells, June 2011
There is only one 'control dial'.
This could be any number of things between pump, fan, fps, and 4 pcbs, (it could even be external to the appliance).
Without delving too deep, try disconnecting the 240v motors (pump & fan), then switching on, if no fuses blow, it's a process of elimination between the two. If the fuse still blows you will need to get someone reliable in to check it as it is a potential minefield to track down.

Carefree, June 2011