Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

Powermax 155x Backfires after running for 30-60mins?

I have had the boiler serviced and a part replaced. When the boiler is first switched on the usual ignition is fine but once it has run for 30-60mins and the ignition needs to kick back in, it Pops/Backfires. I take it as the Gas is running through and the Ignition has a delay and the chamber fills with Gas and when the element heats up the ignition has greater volume of Gas than required, hence the Pop/Backfire. What it the fault and what needs replacing?
Laz, November 2011
Found the answer - The Ignition Element was worn and had a 10mm gap across the Sparking Point, instead of a 4mm Gap. Both ignition Element and the High Tension Lead replaced. Problem now fixed

Laz, January 2012