Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

fix low pressure on my boiler?

i have a F37 error on a ferroli boiler. i keep reading about the filling loop but nothing underneath matches the description
keith, December 2011
Filling lop is a flexible metal braided pipe, with a valve, and a non-return valve. Might not be below your boiler. look for a metal braid pipe. Some times, not left connected, Officially, should not be left connected. So look for 2 pipe screw fittings, max about 10inches apart. one would be your cold water mains supply pipe, the other would go to the return of your central heating system. If not there, go and get one. fit it, and off you go.

SD, December 2011