Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Steve asked ... Gilera runner 180 vxr 2001 ignition replacement?    |    Click here to ask your question

Hot water issue?

Halstead ace boiler c/h ok hot water intermitant. Changed diverter diaphram and dhw thermistor still issues. Could the heat exchanger be scaled up?
simpson, February 2012
had this b4 where worked ok on c/h but not on h/w ended up being the fan venturi partially blocked only highlighted itself on hot water because higher burner pressure in h/w mode

hig, February 2012
Hot water heat exchanger scale up need acid clean

ltg, February 2012
link Click here to see other fixes for Halstead Ace.