1 hour ago Cuckoo asked ... Changing batteries on a fixed bt corded phone?    |    Marc Nollid asked ... Nissan Micra mk 5 2018 rear seat mecanism?    |    Maggie asked ... New Home 535?    |    paul asked ... Hook timing Janome QC 6260?    |    David asked ... Beeper bust?    |    Click here to ask your question

bosch worcester 14/19cbi lockout - fires up for 1 second?

my bosch worcester 14/19cbi has lockout light flashing - when i reset it fires up for 1 second and fan comes on then cuts out - this happens about 4 times and then the lockout light flashes again.
G. D. C., April 2012
worcester 14/19 CBi
GCN 41-311-52
ignition problem
fails to detect burner alight
ignition/detection electrode faulty?
maybe shorting to earth via boiler casing?
would need to check condition of wiring between electrode & PCB to determine precise cause of fault

manwithnoname, April 2012
link Click here to see other fixes for Worcester Bosch 14/19CBI.