Boiler goes out after 15 Minutes?

Potterton RS50s flame goes out after 15 minutes.

New Thermocouple fitted, still problem
Graham R, December 2012
check the overheat stat as this also cuts of the gas valve. check also the thermostat on the boiler as it should cut the boiler off at certain temp. if its faulty the boiler will carry on heating causing the safety overheat to cut off the boiler. so it will be one or the other. hope this helps

kash, December 2012