1 hour ago Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

How to repair faulty Boiler?

I have Vaillant eco Tec Pro 24 and when I start open the boiler start ignite for 10 second and shutdown and do like this 2 or 3 time after that stop and in the screen coming F 28,29 I try to clean sparkle and still same could you tell me what I have to do please .
ALI, February 2013
look at the boiler is it firing up. or is there just a blue spark but not firing. if its firing listen to see does the igniter transformer stop buzzing or is it carrying on buzzing after the flame has ignited. if so the spark electrodes need cleaning. there two so clean them both one will be by the flame window the other a bit further away. u need to clean it with sand paper. give it a go then post again if no luck

kash, February 2013