36 mins ago Pekaye asked ... Clutch Cable change?    |    1 hour ago Richard asked ... Mountfield SP414 mower, revs too high?    |    Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Click here to ask your question

Pressure reading over 3 bar?

Hi I have a Worcester 28CDI and recently noticed that the pressure is reading over the 3 bar level previously it was between 1 and 2, can anyone advise how you can reduce pressure every where I look its the opposite ,ie needing more to increase the pressure ,but cant find anything on reducing?
Gill, February 2013
If it is constantly reading over 3 bar then it may either the filling loop has been left open or the plate heat exchanger has pinholed and is cross leaking water from the dhw into ch, to reduce pressure bleed a rad until the pressure is between 1 & 2 bar on gauge, if pressure only rises to 3 bar whilst boiler running the it may be the expansion vessel at fault. If after all that the fault persists then you may need to call a professional or boiler manufacturer for a repair.

Steve, March 2013
u can bleed a rad from the air point it will gradually reduce the pressure as u take the water out

kash, February 2013