Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Steve asked ... Gilera runner 180 vxr 2001 ignition replacement?    |    Click here to ask your question

Worcester 28i Junior Fault Light flashing?

The fault light is flashing 5 timrs fast, pause, five times fast etc.
Martin, March 2017
Ring Worcester technical helpline

They can guide you through a series of simple tests to determine if you can rectify fault yourself or if you require a heating engineer

Asbestos, April 2017
air flow fault, boiler is in a lockout condition if the controls fail to detect the correct air flow through the appliance and the light will flash approx 5 times a second, the appliance will try to re-light after a waiting time of approx 5 minutes, check the flue terminal is not damaged or obstructed, if it doesn't start itself call engineer.

chris p duck, March 2017
http://manchesterplumbingandheating.co.uk/tutorials/boiler-fault-codes/worcester-bosch-fault-codes/

acp, March 2017