3 hours ago Dave asked ... Toilet Push Button not flushing properly?    |    Dave asked ... Repair kettle lid?    |    Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    Click here to ask your question

Baxi Genesis 80 - What's the fault?

Sometimes it works properly but most of the time on DHW it ignites, burns for a very short time (1 or 2 seconds), goes out, re-lights, goes out, and keeps repeating this. On CH mode it ignites, burns for a bit longer (a few minutes) and then cuts out with no more than 2 or 3 LEDS glowing and rads only warm, it then takes a long time before it re-ignites and goes throught the same process.

The 3 way valve, flame sensor, spark ignitor, pressure switch, prv, safety thermostat and pcb have all been replaced. The system is holding pressure. Repairs are costing a fortune!

Any ideas?

Thanks.
Paul, February 2007
sounds like your flue venturi could be blocked or partially blocked

randal, September 2007
link Click here to see other fixes for Baxi.