David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Michael asked ... Mountfield empress drive belt?    |    John Barton asked ... How do i clear the TAM?    |    John asked ... How can I mend my binatone veva 1210 handset?    |    Click here to ask your question

danfoss fp75 control panel for glowworm ultimate boiler?

danfoss fp75 control panel for GLOW WORM ULTIMATE boiler has a small battery icon flashing permanently resulting in boiler not working even though the unit has not been disconnected from mains as stated in booklet any ideas as i cannot get heating/water
harry, April 2007
I just done this also, it is a real pain to get the battery off as it is micro welded onto the connection plates..

I removed the connector plates by unslodering them from the board and bought a new battery and a battery holder from maplin.

Holder £0.45 and the pins fit right into the holes on the board, i recon they are a standard size.

I found it impossible to fit the battery back onto the original plates...

Sparkymalarky, September 2008
Hi Harry
I had exactly the same problem this morning.
Undo the 2 screws at the bottom of the unit and lift unit up, off its wall mounting (careful as the wires behind are live)

Turn the unit round - and undo the 4 screws on the back (again be careful as the buttons may fall out of their holes!). On the back of the circuit board is a round, 3v lithium battery. Unfortunately, its kind of pinned to its connectors so you'll have to use a pair of pliers to prise it out.

The reverse the procedure, making sure the battery is well connected to its terminals.

Good luck
ali

alicoates, April 2007