Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

worcester 24cdi rsf combi?

my pressure keeps dropping to 0 on the gauge. i refill it to one and a half bar but after about a week it goes down to zero. do i have a leak under the floor or is there something wrong with my boiler?
albert, April 2007
if the leak is from a heating pipe yes thats why.

hi-spec plumbing, April 2007
The most common fault is pressure relief valve/safety valve not seating properly and allowing water to pass through the vent pipe outside.Tie or tape a plastic bag to the end of the vent pipe and see if it fills with water.

John Warner, April 2007
link Click here to see other fixes for Worcester 24CDI RSF.