Freya asked ... Frister & Rossman Cub7 Sewing Machine?    |    katlego asked ... Rev count on my 1982?    |    andrew asked ... "SECURE" on a yellow backround, and I cant ge?    |    Melodie asked ... How do I remove and change the basket? Duratech Identity Gu?    |    Kathy asked ... Samsung ER-4915?    |    Click here to ask your question

Glow Worm Swift Flow - Pilot Light Does Not Ignite?

Hi,

I was wondering if anyone would be really kind to help me. Our boiler s pilot light will not ignite, I do not have any clue as to why. A couple of days ago the pilot light kept going out but when we re-igniting it, it worked fine but cut out like every couple of hours. But not it barely ignites at all. I would be really grateful of any help.

Thanks
Mitch, August 2007
Hi Carl,

I really appreciate your help, my step dad replaced the thermo coupler a couple of months ago which solved the problem but then then this problem has cropped up. We found that first of all our gas setting was at the max on the boiler which was most likely putting all of the components under strain. We have now replaced our circuit board as we had a spare from previous repairs and the boiler now seems to be fine. I really appreciate the help you've given..... Thanks

Kind Regards

Mitch

Mitch, August 2007
hi
sounds like the thermo coupler is faulty. 99.9% sure this is the probem.
easy fix all ou need is new thermo coupler buy a universal one cost around £15. look in boiler you will see a thin copper wire on both ends there is a nut. undo the nuts pull out and re-fit new one. simple as that. any problems or q mail me on taz2023@talk21.com
carl

carl, August 2007