Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

Vaillant turbomax combi hot water problem?

just had a new diverter valve fitted as we were getting no hot water. (central heating fine) problem still exists water now only luke warm any answers?
Chris Dunn, October 2007
or gas meter reg

mrgas, October 2007
either return ntc sensor failed, pipework in boiler blocked causing rapid temp rise or auto bypass on boiler blocked causing div valve to jam in htg position. dpmartin17@aol.com

paul martin, October 2007