4 hours ago Dave asked ... Repair kettle lid?    |    Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Click here to ask your question

Vaillant turbomax combi hot water problem?

just had a new diverter valve fitted as we were getting no hot water. (central heating fine) problem still exists water now only luke warm any answers?
Chris Dunn, October 2007
or gas meter reg

mrgas, October 2007
either return ntc sensor failed, pipework in boiler blocked causing rapid temp rise or auto bypass on boiler blocked causing div valve to jam in htg position. dpmartin17@aol.com

paul martin, October 2007