2 hours ago Sandy asked ... Replace vertical gear on Singer Fashion Mate 252?    |    Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Click here to ask your question

heating problem, whats wrong please?

chaff britony combi 80. hot water fine, heating problem comes on low rate 10 secs then off cycles again when htg on constant.no rads htg at all.pump hot but ok no air locks.suspect dhw switch stuck in dhw position or stuck diverter valve?any help appreciated.thankyou
mike bonning, November 2007
To check if its the 3 port valve (diverter) check the lever on the motorised head to see what setting its on as when calling for heat it should be either mid position or heat. To get heat on the tempory basis try moving the lever manually and if it works take off the head and fit the valve to mid position whilst you arrange a replacement.