Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

no hot water sime super 90?

when i run my hot water tap slow the water goes cold and the boiler cuts out
alan, October 2010
A combi boiler requires a certain flow rate at the tap to stop boiler from overheating and cutting out. So by cutting back your tap to slow , you are not allowing this and the boiler is cutting out. Open your taps more to allow a good flow rate, if water not warm enough then flow rates have to be adjusted by gas boiler engineer. If this doesn't help u have a diverter valve problem.