7 mins ago Ariana Orellana asked ... Code?    |    Lynnie asked ... BT Studio 4500 cordless telephone?    |    David Dawes asked ... How to recoil the starter spring - Champion R484TR?    |    peter high asked ... How can I set time on my Neff oven?    |    Michael asked ... Mountfield empress drive belt?    |    Click here to ask your question

Miele Diswasher?

Hi i have a Miele G 1270 SCVI and i am getting a FO1 fault. i ahve googled it and it seems that the causes and remedy could be the following: Cause:
NTC temperature sensor R30 or its connection leads short-circuited. would you know how to acess the temperature sensor since i would like to change or test it thanks?

Remedy:

1. Check the temperature sensor and its leads for continuity. At 68°F (20°C), the temperature sensor resistance should be approximately 14.9kΩ (± 750Ω); at 77°F (25°C), approximately 12kΩ (± 600Ω) (guide figures only).

2. Check the plug connections.

3. Replace the temperature sensor, if necessary.

would you know how to acess the temperature sensor since i would like to change or test it thanks
matthew, March 2013
link Click here to see other fixes for Miele.