How can I mend my Scantronic 9800 intruder alarm?

My Scantronic 9800 intruder alarm was triggered by power being restored after a power cut. It initially showed an lb fault code after being silenced following me keying the code. At this point I swit ... more


Logik 4 panel?

Logik 4 alarm..not used for 8 years..how do I set it up


done

House alarm Scantronic 9427?

Scantronic 9427 panel has no lights. Replaced three fuses in inside metal case and also fitted new battery. Still nothing showing on scantronic panel. Bleeping sound from internal alarm.


done

How can I mend Scantronic 9751 Panel?

Scantronic 9751. 9941 Keypad: Amber Pulse Warning Triangle light Hi, after what I believe was a power cut, my panel went completely dead, I replaced the 12v battery for my 9751 Scantronic alarm as ... more


Problem setting my alarm?

I have Optima plus 2 alarm system .When I go to set the alarm it keeps showing zone 1 and keeps beeping not setting.Zone 1 is the front door.Any help will be appreciated.L.G.


Alarm home system?

accord home alarm not working when enter code


Honeywell alarm?

how to resolve fault on honeywell ade gen4 remote keypad . display shows a line of black squares. alarm panel is accenta 8sp399a


Centrale di allarme st6000 manuale?

per favore posso avere il manuale di programmazione di questa centrale st6000 melcom anche pagando? ho smarrito tutto, grazie


Accenta 8?

My granddaughter pressed the attack alarm in a bedroom, alarm went off, my son entered the alarm code but didn't press Reset, the attack light is showing on the Accenta 8 panel and the strobe light on ... more


done

Optima Plus security system?

I have an old Optima Plus system, just had the back up battery in the upstairs control panel changed, since then the downstairs control panel will not activate, it has the power on light, but nothing ... more


Rascal plus?

The primary exit tone does not change and activate the system


Help bf fault?

Hi I have a series 3200 plus alarm with bF fault - think from look on line and here it could be control panel battery fault? I have called my and left a message for the last person that serviced this ... more


Logic 4 Alarm advice needed?

Logic 4 Alarm system key version. I need to get rid of one of the alarm detectors that's in a bedroom. How do I do it? Tried unwiring it but it just sets the alarm off. I don't have a manual as the s ... more


Optima xm alarm problem?

I have an old wired optima Xm alarm system with 5 pir, it worked okay until a few weeks ago. It went off itself when in day mode. I replaced the battery and seemed okay for a couple of weeks. It went ... more


How to fix my Texecom Veritas Home Alarm Power issue?

Hi - I have a Texecom Veritas 8 system. There was a power cut while I was not at home and it has never recovered properly. Power light at keypad was flashing and LED display was visible but not illum ... more


done

How do I rewire the door entry detector?

the entry door sensor dropped off while changing the door. We are struggling to wire the unit back up. SECURIT 800L control panel


Cooper menvier 9448 alarm?

Cooper menvier 9448 alarm showing tamper look broken


Need Engineer code for Scantronic 9800 alarm?

I have an E code showing on my Scantronic 9800 alarm after I changed the battery, cannot reset the alarm and nothing clears the E code, do I need to enter an engineer code? if so what do I enter?


Opitma plus 2?

How can I reset alarm showing red A flashing Opitma plus 2


done

How can I mend the battery fault on my TSD401 alarm system?

how do I stop the batt fault alert on my TSD401 alarm system