Fix Fault Aquatronic

labellabel_off

check_circle Free repair help

We have 186 questions about fixing 'aquatronic'

Unable to reduce water temp from very hot on our aquatronic power mixer sho?

We have just moved house and inherited an aquatronic power mixer shower. Power is fine but the shower is too hot even when we set temp dial to its coldest.


i have an aquatronic 2?

When the shower is turned on the water comes out the shower head and also it gushes out the bottom left , can this be repaird thanks


Aquatronic 3 electric shower running cold?

The shower has recently stopped heating the water even when turned to max temp. Initially it would get very hot at max temp setting then as soon as turned down would suddenly switch from hot to cold. ... more


Low output pressure, aquatronic 4?

Low output pressure, aquatronic 4.when dial set to required temperature. When dial turned to cool full pressure resumed. Can you recommend a test or part required.


How can I fix my aquatronic 2? ?

My shower needs to be turned upto 9 for it to give out hot water, any ideas why or what I can do to fix it?


done

Aquatronic 4 plus shower unit?

When Switching on the shower, the shower runs cold. I turn it up to maximum temperature then the hot water kicks in gradually reducing it to the temperature required. Sometimes this works other time ... more


aquatronic 3 not working?

can u plz help my aquatronic 3 shower is not working there is no water coming out of the tap is only six months old.


No water from shower?

my Aquatronic shower when switched on makes a whurring noise but no water comes out. The shower has been working satisfactorily up until now.


aquatronic 4 shower?

the shower will not stop even though it is switched off - cold water just keeps running - is it something we can fix or will it have to be a new unit ?


done

3 year old triton aquatronic 4 plus electric shower fault?

The above shower has suddenly started lighting up low pressure after approx 30 seconds of use then running cold , pressure on bathroom tap is same as always.Shower is cold mains fed and supply is from ... more


done

Aquatronic w9500i leaks when on ,and has to switched off at mains?

My Aquatronic w9500i leaks water through the bottom of unit when on,and has to be turned off by a seperate switch. The water leaking out is from a valve inside the machine. The switch normally used ... more


want to stop the water?

i got aquatronic 3+ shower when turn the shower off water still coming how do i stop the water


Scalding hot water from shower?

I fitted a new aquatronic 1 shower last week and commisioned it as per the instructions. It has worked fine until this morning when the water ran scaldingly hot. The heat gauge was set to 6. I ... more


done

I have no hot water coming out my aquatronic 4?

i have no hot water coming out the shower what part needs replacing .its a 9.5 kw.


done

aquatronic thermostatic power shower Ko3?

My shower has stoped working, theres power to the unit theres also water , any idea It cant be much older then 18 months


Temperature problems with Aquatronic 2 shower?

The shower is cold when turned on, so I have to turn it to the highest heat setting.The shower sounds like its boiling then I have to turn down the heat setting but it goes really cold, temperature is ... more


Aquatronic 2 how to fix?

I have an Aquatronic 2 shower and it worked fine for about three years, now when i turn it on it just trickles from the shower head, there just no power at all is it a pressure problem? does anyone h ... more


done

aquatronic w8500 prd?

the little black ball has come out of the clear pipe underneath my aquatronic w8500 and now it leaks water,ive replaced the shower head as it was blocked and im not sure what to do about the leaking ... more


done

sorry?

but what is a prd in relation to a leaking overflow on an aquatronic 4 electric shower???


done

water pouring out of overflow pipe?

aquatronic 4 shower water is flowing out of the waht i think is the overflow pipe at the bottom of the casing just by the hose connector.......how fdo i fix this problem


done