We have 344 questions about fixing 'potterton netaheat'

replacement for honeywell pressure switch ?

I know the switch # c6052a1015 is obsolete. most listed replacements are adjustable. I need to know the rating of the original part. This is for a Potterton Netaheat 66E. What I am really asking is fo ... more


Potterton Netaheat M11 no heating no hot water?

The boiler lights up and gets very hot and then closes down. We have replaced pump and fan. Zone valve working. Rads are not heating up and cold water.


done

Potterton Netaheat Profile 60e banging when firing up?

When the boiler 1st fires up it sometimes makes a loud bang as it does so - assuming due to extra build up of gas. Any ideas what can cause this? I though it might be either piezo not firing 1st time ... more


done

My potterton netaheat electronic balanced flue gas boiler 6/10 does not wor?

pilot light light, but main burners do not,why?


done

i have potterton 50e netaheat bolier stat keeps clicking?

Thank you for your reply that it could be the PCB.But this clicking keeps happening while the boiler is fired up and all the burners are on.its every minute of so and the burner is still burning.this ... more


done

i have potterton 50e netaheat bolier stat keeps clicking?

My POTTERTON 50E boiler will fire up ok but after awhile that it has been working for I will hear the stat in the bolier keeps clicking every few minutes and nothing happens,this will keep clicking un ... more


done

what part need changing?

it's a potterton netaheat profile conventional boiler,it's stop firing for hour at a time on a cold day.What part need replaceing.


vent pipe is venting hot water and cold feed from haedertank is getting hot?

heating vent pipe is venting hot water and the cold feed from tank is getting hot and pumping hot water into the boiler. the boiler is a potterton netaheat mk2 1016.


done

over heating boiler?

boiling water coming from open vent pipe and hot water is coming up the cold feed into the header tank...potterton mk2 f netaheat 1016


done

potterton netaheat boiler stat?

How can I test my boiler stat is operating correctly their is no cylinder stat fitted new thermostat that seems to be working correctly, but boiler appears to be on almost constantly, so how would I t ... more


done

Help?

Potterton Netaheat Profile 80e We have just moved into the house and the boiler is not fieing up,the motor is running but the pilot light is not on. Any help Thanks


Potterton Netaheat balanced flue - pilot light?

The pilot light would fire and all the cental heating would work fine but just recently the pilot light would fire then go-out and refuse to operate leaving us with no central heating. Could it be the ... more


done

Potterton Netaheat - no heating without hot water?

Boiler will only fire up when "hot water" selected on controller (EP2002). When hot water is on, radiators also heat up (whether or not the heating is set to "on" on the controller) but cool down whe ... more


done

Potterton Netaheat boiler and heating system?

My heating won't come on unless the hot water is on and heating up. Once the water has reached it's temperature, the boilers switches of and thus the heating goes off too. also the overflow pipe in t ... more


netaheat electronic 10-16?

hi all my potterton was working but now fires up but stays alight for a short period then switchs off. the first rad on the run gets hot but thats all so the water is pumping round i thinking some kin ... more


done

How to repair a Potterton Boiler (Netaheat 10/16 Potteron GUK124788)?

From the heating system there is no hot water and the radiators are not heating up either. From the boiler the fan is working but the pilot-light is not coming on. Have checked the air pressure/air pr ... more


done

Potterton Netaheat Ptofile 60e spares?

I have the above boiler fitted but want to reposition it. I have been told that I will need a new flue to be able to do this does anybody know where I can get this part. Thanks


done

Potterton Netaheat mk2 central heat works but not water?

If I have the central heating and water on then it heats up the heating fine. But with only the water on it does not fire up at all.


done

Potterton Netaheat 6-10 electronic?

Pleas advise what might cause a fuse to blow on control unit 407676? I don't think the problem is the unit could it be the fan?


done

how to fit a p.c.b. to potterton 40e ?

how do i fit new p.c.b. to my potterton netaheat 40e


done