Fix Fault Ravenheat

labellabel_off

check_circle Free repair help

We have 759 questions about fixing 'ravenheat'

ravenheat ls100t flame failure switch?

my flame failer switch keeps coming on,i have tried system restorer added to the radiators,to clean any debris from the sensors,but has not worked,could it be the electrodes


done

PILOT WILL NOT STAY ALIGHT?

The pilot light keeps going out after i use hot water or the central heating has been switched off? i have a ravenheat RSF 820/20T fanned combi boiler, had thermocouple and gas valve changed but still ... more


done

Ravenheat LS 100T no DHW?

Been informed on this website that it is either the microswitch or diaphragm, could anybody please tell me how I can remove and rapair these items.


done

Ravenheat LS 100T no DHW?

First off I have had this boiler for 2 yrs now and never had a problem before, the other day all of a sudden I have got no hot water, the central heating is fine and the water flow is still good but i ... more


done

ravenheat combi boiler(rsf84et)?

hello can any body help me ? has any body had simillar problems with ravenheat combi boiler RSF 84 ET ? NO HOT WATER AT ALL (6 MONTHS) CENTRAL HEATING INTERMITANT (O.K SOME TIMES ) PLUMBMER CAME ... more


done

ravenheat csi 85?

flame failure light comes on immediately when both turning ch or dhw on.ravenheat csi 85.


done

Ravenheat CSI 85 no DHW unless CH on?

Hi, I have a problem with a Ravenheat CSI 85 (18 months old) which will only give DHW when the CH is on. If turned to DHW mode the boiler will not fire. I have checked diverter valve which ... more


done

whats wrong with my ravenheat boiler?

there is power going to the boiler but northings happernig ?


done

Ravenheat RSF 820/20.Hot water luke warm?

When taps are turned on the combi boiler fires up and for less than a minute the water is hot. After that the water goes luke warm,checked boiler at this time,boiler still fired up. Any one help me ... more


done

ravenheat combi boiler hot water not working?

i have a ravenheat combi boiler even though the central heating side is working the hot water side isnt any ideas what it could be


done

ravenheat ls 100t combo boiler?

d.h.w cycles on and off, boiler works fine in c.h.mode possibly d.h.w/c.h.potentiometer or d.h.w/c.h.sensor.


done

how to fix ravenheat boiler?

central heating ok but hot water goes hot and cold


done

Ravenheat CSI 85AT boiler tripping problem?

Ravenheat condensing combi boiler CSI 85AT fault? My 1.5 year old boiler has developed a random & intermittent tripping fault, in both modes of heating (i.e. CH & DHW). With the remote programmer c ... more


done

Ravenheat condensing combi boiler CSI 85AT fault?

My 1.5 year old boiler has developed a random & intermittent tripping fault, in both modes of heating (i.e. CH & DHW). With the remote programmer calling for heat or the hot taps turned on, it often ... more


done

Problem with Ravenheat LS100T combi boiler with built-in timer?

I have had the above boiler for about 2 yrs now. But in the last 4 weeks, it has not been working perfectly. Whether heating on or off, when I turn hot water on, it gives me sometimes hot or col ... more


done

ravenheat boiler820/20 switches its self on & off by the electric timer?

my boiler keeps turning its self on & off via the timer unit all the time.The unit keeps loosing its memory and flashes all sorts of timings.I have replaced the unit once before due to the same proble ... more


done

enheatrsf 820/20 boiler keeps turning its self on and off via the tim?

my ravenheat 820/20 combi boiler keeps turninig its self on & off via the timer unit . what would cause this problem?


done

My 18 month old combi boiler is leaking?

Hi, I have a Ravenheat Condensing Fanned Combi CSI 85T only 18 months old and it has started to leak. The boiler is situated in the airing cupboard in the bathroom. The plumber has been to this probl ... more


done

heating not working?

just fitted a new ravenheat combi works fine on hot water but the heating only fires up for a few seconds and the flow pipe gets hot up to a meter then it shuts down


done

ravenheat boiler?

i have a ravenheat ls100 white star the bioler works ok when the hot water is turned on but will not work when heatin is put on can any 1 help thanks


done