Fix Fault Halstead

labellabel_off

check_circle Free repair help

We have 537 questions about fixing 'halstead'

Halstead Ace Lockout Problem?

I have a porblem on my Halstead Ace Combi Boiler where the 'Burner On' and 'Lockout' buttons have come on resulting in no heating or central heating. Any ideas?? - Thanks


why does boiler keep ejecting water from c/heating?

halstead boiler combi 82 keeps ejecting water from c/heating when running central heating even when central heating boiler thermostat turned down low why is this and how can i remedy this


done

Halstead Finest Gold Combi Boiler LOOSING WATER FROM THE BOTTOM OF IT?

We kept noticing the pressure on the boiler kept going down and we're having to top it up. We have now realised it is loosing the water from the bottom of the boiler. Will this be a case that the hole ... more


done

halstead ace high?

hot water poor has gradually got worse over a year and now cuts out


boiler pressure?

I have a Halstead Ace High Combi boiler. The pressure in the boiler keeps dropping below 0.5bar then it shuts off. When i open the valve below the boiler i must be repressurising the boiler with water ... more


I have to "top up" my Halstead boiler every day?

The pressure drops when the boiler is off, when left overnight it is almost on zero, and I have to top it up. I have checked all the pipe work and can't find a leak.


done

Why blockout is on?

Whne blockout is on, I connot get hot water supply. The pressure meter from bar 2 drop to bar 0. This boiler is made by Halstead Boiler Ltd. THe model is Wickes 102 Combi. Please halp me to slove ... more


Halstead ace he 30 condensor leaking?

Hi my halstead ace he 30 has a small condensor box below it which has just started getting really noisy and sometimes has water leaking out, its just over 2 years old do i need to replace it or can i ... more


done

What pressure should the pressure gauge be set at?

The pressure gauge on my combination boiler (Halstead Finest Gold) is set at 1.5 bar and this increases to 2.5 bar once the heating has been on a short time. I am worried that this is too high. ... more


done

halstead combi boiler?

on my combi boiler the heating works fine but the hot water has packed in just cold all time


done

halstead ace?

my heating is working but the hot water not firing up


boiler wont ignite!?

i have a halstead boiler and it was working fine except for DHW fluctuated,, changed the plate and now the boiler will not light although goes throught the sequence,, but can not hear the sparking for ... more


done

how can i fix halstead finest gold boiler?

i have a halstead finest gold boiler, water is coming out the pressure relief pipe when over 2 bar of pressure. would you think the pressure relief valve is shot? if so could i replace it easy? than ... more


done

Halstead Quattro - Fires up, but no HW?

Hi. I know there are similar posts on here, but not exactly the same. Okay, this is the problem - even with the CH set to off, turning on the hot tap fires up the boiler immediately (so according to o ... more


done

halstead combi dhw fault?

have an ace high combi model which responds and ignites to dhw demand, yet the water stays luke warm then sometimes gets to the correct temperature, i have checked dhw thermister n flow switches, all ... more


done

Halstead Finest Gold Combi Boiler?

I have a Halstead boiler which is loosing water via the overflow, this then reduces the bar pressure and stops the hot water from firing. Can anyone help me please and let me know what needs to be fi ... more


done

HALSTEAD RFTH 1 CONTROLLER?

COULD SOMEONE PLEASE TELL ME HOW TO REPLACE THE BATTERY IN THE CONTROLLER & WHAT TYPE OF BATTERY DO IT REQUIRE


done

Manual for Halstead Quattro Gold Boiler?

Can anyone let me know where I can obtain a new manual from for my boiler as I can't remember how to change the timer etc?


done

The locked out light has come on on my Halstead Ace high combi boiler?

The red locked out light has come on on my boiler and there is no CH or hotwater! Does anyone know what the problem may be and can I fix it myself?


done

boiler will not fire up?

i have a halstead he30 ace boiler, fan and pump kick in but will not fire up. have been told that it could be the air flow switch. need help as i have run out of money trying to do the old place UP! ... more


done