Fix Fault Vokera

labellabel_off

check_circle Free repair help

We have 1625 questions about fixing 'vokera'

wiring a nest heat link to a vokera 25 he compact ?

trying to wire a nest heat link to a vokera 25 he compact boiler already blown fuse need help


done

Vokera combi.i ask for hot water or heating it locks on red?

When i run the shower or use the hot tap my Vokera combi locks on red. What can i do to fix this .


Vokera excell boiler needs topping up every couple of days ?

My boiler needs topping up every few days there are no apparent leaks in the system. the only clue is the pressure relief valve blows off thus discharging the water. Could it be the directional valve ... more


done

Vokera Mynute 28 SE Fault?

When my Vokera Mynute 28SE boiler is in operation the pressure rises then drops as the boiler cuts out every minute. I am unable to reduce the pressure under two bar as it always settles at that leve ... more


fuse blowing on a vokera activa HE combi boiler?

my vokera activa HE combi boiler has started lowing fuses every other day or so. up to about a week ago it was working O.K.


I have a Vokera 24 that shows error code 07. can anyone help me fix it?

My Vokera 24 is 10years old. it has been very good up to now. It shows error code 07. The pump works but no h/w or heating. the pressure is at 1.5 bar. is it time to part with it, or can anyone help m ... more


done

vokera 12-48rse?

where is the ignition switch on a vokera 12-48 rse the pilot light has gone out as the water pressure was too low


done

I have a linea 24 vokera boiler with 06 fault?

The pressure was dropping before the fault comes on continually. Any ideas of the problem and appropriate cost to fix.


low pressure?

what can cause low pressure in my vokera 29a combi boiler if no leaks are found


Boiler problem?

The pressure needle on My vokera boiler bounces when I turn on my hot water tap..I fill the cntral heating system up but the pressure drops dramatically overnight and reads nothing again in the mornin ... more


how can I fix my Vokera linea 24 Combi?

the boiler cuts out whenever I use either the hot water or the central heating. lo displays after I re-pressure it ,it cuts out again. the hot water and heating only works for about 3 minutes. ple ... more


done

Vokera 29a compact?

Boiler fires up for hot water no problem but also fires up for heating for around an hour or until boiler reaches temp but won't come back on again for hours, is this a thermostat problem??


how to ignite voker pilot light?

vokera boiler no piot light how to ignite


done

water drips from overflow?

i have a vokera compact fitted 2-3 years ago,now pressure needs topped up every other day works ok apart from this.water drips from overflow,can you tell me which part is faulty.thanks


done

How can i fix my vokera linia 24 boiler?

There is power going to the boiler and the 2 internal fuses are ok . But boiler does not indicate power there (no temp or fault code numbers ilumanated)boiler obviosly doesnt fire up


done

'a' in display box?

Hi have inherited a vokera boiler in a house \I have purchased. Boiler working ok until electricial turned electricity off to do some work. Resulted in 'a' in display box. Do I just need to reset the ... more


why does heating come on when i turn on hot water tap?

I have a vokera compact 29 HE. No matter wether I have the selector on for heating and hot water, or hot water only, the radiators warm up, when ever I turn on a hot tap, and the hot water is cool unl ... more


vokera ch flow valve dripping?

vokera excell sp 80 combi , CH flow valve underneath boiler is dripping water , when ch is off or on . Is there a way to tighten this up or a way to stop it leaking


bubbling sound?

my vokera vision 25c is making a very loud bubbling noise when running chap from vokera wont be here until wed of next week ....help


Replacing pump on Vokera Linea 24?

Seems to be leaking from the back of the pump right in the centre. Is there a simple fix or do I replace. Thank you